ITQ Series GC-Ion Trap MS

  ITQ Series GC-Ion Trap MS



Thermo Scientific* ITQ Series GC-Ion Trap MS offers outstanding full-scan electron ionization sensitivity and upgradeability.

   Product Detail


From a small-footprint entry-level QA/QC instrument to a fully-featured, research-grade system with advanced MSn functionality, the Thermo Scientific ITQ Series offers a broad range of standard features along with an impressive list of options. As needs change, the ITQ Series offers upgrade options to expand instrument capabilities and add flexibility and versatility. The ITQ Series is supported by Productivity Solutions and workflow-oriented software packages.
External Ionization Ion Source
  • Standard on all ITQ systems, with independently-controlled heating from 125 to 300°C for stable operation and excellent chromatographic integrity
  • Spectral integrity is enhanced when ionization takes place external to the trap, and the system stays cleaner longer, for improved uptime and longer periods between cleaning
Quadrupole Ion Trap Mass Analyzer
  • Unit mass resolution throughout the mass range
  • Durable inert materials for long life
  • Automatic gain control ensures that the ion trap is always filled with the optimum number of ions
Detection System
  • Digital electronic noise discrimination enhances sensitivity
  • Post-acceleration +10kV conversion dynode offers efficient positive and negative ion detection

Configurations Available for ITQ Series
  • Direct Sample Probe
  • Directly analyze solids or liquids without chromatographic separation and without moving the GC by using the Direct Sample Probe
  • Chemical Ionization
  • Use chemical ionization for added selectivity and sensitivity
    Both positive and negative chemical ionization modes are supported, and digital reagent gas flow control ensures method stability and reproducibility
Features Standard on the ITQ 1100, Optional for ITQ 700 and ITQ 900
  • MSn with ACE and PQD
  • Routinely test for compounds in matrix that cannot typically be detected with other GC/MS techniques
    Automated Collision Energy (ACE): Automatically calculates an estimated optimal collision energy based on product ion m/z and damping gas flow rates; Runs at three energies across each scan
    Pulsed Q Dissociation Mode (PQD): Generate information-rich mass spectral data, even in the low mass range; Produces precise, reproducible fragmentation
  • Vacuum Probe Interlock
  • Restore system performance, change from EI to CI, or use the direct sample probe, all without venting the instrument using the Vacuum Probe Interlock
 
Related Products
 Product# Product Name Image  
 
IQLAAAGAAH
FACHMAFW
 
FOCUS GC Gas Chromatograph
  Select   
 
IQLAAAGAAH
FAFUMAMR
 
TRACE GC Ultra
  Select   
 
IQLAAAGAAI
FAINMAQQ
 
Thermo Scientific ITQ 1100? GC/MSn
  Select   
 
IQLAAAGAAI
FAINMAQO
 
Thermo Scientific ITQ 700? GC/MS
  Select   
 
IQLAAAGAAI
FAINMAQP
 
Thermo Scientific ITQ 900? GC/MS
  Select   
 
Purchase Details
SKU : IQLAAAGAAIFAINMZZZ 
Request Quote
Product Contact
 Sales Contact
  Service Contact
 
Literature Request
Postal Mail:
  • AI 3000/AS 3000 II Autosampler Brochure
  • TriPlus Autosampler Brochure Request
  • Electronic Mail:
  • TriPlus Autosampler Product Specification (PDF)
  • Direct Sample Probe Product Specification (PDF)
  • Specifications:
    Postive Chemical Ionization Installation Spec :100:1 RMS S/N using 100pg of DFBZ at m/z 363 (methane) 
    ITQ 700 GC-Ion Trap MS :ITQ 1100 GC-Ion Trap MS
    Gas Chromatograph :TRACE GC Ultra, with 3 detector and 2 injector positions 
    Mass Range :10-1100 amu 
    Negative Chemical Ionization Installation Spec :1000:1 RMS S/N using 1pg DFBZ at m/z 362 (methane) 
    Advanced Scan Modes :Automated Collision Energy (ACE) and Pulsed Q Dissociation Mode (PQD)
    Dimensions (H x W x D) :44 × 33 × 68cm (17 × 13 × 27 in)
    EI Full Scan Installation Specification :100:1 RMS S/N, using 1 pg OFN at m/z 272 
    Source Type :External Ionization, Solid Inert 
    Vacuum Probe Interlock :Standard
    Vacuum System :250L/s turbomolecular pump
    Weight :45kg (98 lb)